Heating Cable CW-SR 20M

Complete product

€170.77 /piece

Incl. VAT, excl. shipping costs

Delivery in 2–5 business days

Pay now

Apple Pay Google Pay VISA Mastercard

30 days to return

EAN
5907599623069
SKU
TF-CW-SR 20M
Categories
Heating cables and wires, Self-regulating heating cables

Quick variant selection

This product comes in several versions — choose the one you need

Heating cable TF-CW-SR 20M

Self-regulating pipe freeze protection

TERMOFOL TF-CW-SR is a self-regulating heating cable that protects pipes and water pipelines up to 2″ in diameter from freezing – including pipelines running underground. The cable can be installed inside the pipe or on the pipe under thermal insulation.

The heating power adjusts itself to the temperature, so the cable does not require a thermostat.

10 W/m
Unit power
200 W
Total power
20 m
Cable length
IPX8
Protection rating
Pipe with heating cable TERMOFOL TF-CW-SR in a trench next to the building

Principle of operation

How does the self-regulating TF-CW-SR cable work?

  1. 01

    Installation inside or on the pipe

    The cable is inserted into the pipe through a tee fitting with a TF-CJ installation reducer, or laid on the pipe under thermal insulation.

  2. 02

    More heat in frost

    As the temperature drops, the self-regulating core of the cable increases the amount of heat emitted.

  3. 03

    Less power when warmer

    As the temperature rises, the cable limits its own power – without a thermostat.

  4. 04

    Winter season protection

    The cable protects the installation during the frost period; when the outside temperature is positive, disconnect it from the power supply.

TF-CW-SR heating cable

Self-regulating heating cable with a power of 10 W/m, ready for connection – with a 2.5 m long power cord terminated with a hermetic plug. Variants ranging from 1 to 35 m in length allow you to select a cable matching the length of the protected pipe.

series:

  • TF-CW-SR
Check available variants →
Self-regulating heating cable TERMOFOL TF-CW-SR

INSTALLATION

Two installation methods

The cable can be inserted into the pipe through a tee fitting with a TF-CJ installation reducer – without disturbing the insulation – or laid on the pipe and insulated. Installation on the pipe is recommended when the installation does not yet have thermal insulation.
On the pipe under thermal insulation

On the pipe under thermal insulation

Inside the pipe – through a tee fitting with a TF-CJ reducer

Inside the pipe – through a tee fitting with a TF-CJ reducer

Spirally on flanges and fittings

Spirally on flanges and fittings

Installation inside the pipe requires a tee and the TF-CJ mounting reducer (for 1″ and 3/4″ tees) – these are not included in the set. On plastic pipes, aluminium tape is applied under the cable. The power supply must have a residual current device with a sensitivity of max. 30 mA.

TF-CJ installation reducer

Brass TF-CJ installation reducer is a dedicated accessory for TF-CW-SR cables, needed for installation inside the pipe. It allows for proper lead-in of the cable into the installation and ensures tightness at the installation point.

Fits 1″ and 3/4″ plumbing tee fittings. When installing the cable on the outer surface of the pipe, the reducer is not needed.

series:

  • TF-CJ
See the TF-CJ reducer →
Brass installation reducer TERMOFOL TF-CJ for the TF-CW-SR cable

Self-regulating heating cable TERMOFOL TF-CW-SR – protection of pipes against freezing

TERMOFOL TF-CW-SR is a self-regulating heating cable designed to protect pipes and pipelines from freezing. It performs well in installations exposed to low temperatures, including underground pipelines. It can be used on pipes with a diameter of up to 2 inches.

The most important feature of the cable is its self-regulation technology. The cable automatically adjusts the heating power to the temperature – when it gets cooler, it increases the amount of heat emitted, and as the temperature rises, it reduces the power. This ensures effective protection of the installation and does not require the use of an additional thermostat.

TF-CW-SR can be installed on the outer surface of the pipe under thermal insulation or inside the pipeline. The cable is approved for contact with water and has an IPX8 protection rating, allowing it to operate in conditions requiring high resistance to water exposure.

Main advantages

  • effective protection of pipes and pipelines against freezing,
  • self-regulation of heating power depending on temperature,
  • no need for an additional thermostat,
  • installation possible inside the pipe or on its surface,
  • can be used in underground pipelines,
  • approved for contact with water,
  • protection rating IPX8,
  • power supply 230 V, 50/60 Hz,
  • maximum operating temperature +65°C,
  • installation possible at temperatures down to -25°C,
  • power cable length 2.5 m with a sealed plug.

TF-CW-SR is a practical, maintenance-free solution for securing water installations for winter – especially where automatic adjustment of heating power and the option of choosing the installation method are important.

Important: when installing the cable inside the pipeline, an appropriate installation reducer for TF-CW-SR is required. The reducer is not part of the set and must be purchased separately.

Cable length 20
Power [W] 200W

Anti-freezing Application

Self-regulating heating cables TERMOFOL TF-CW-SR are designed for protecting water pipes and pipelines from freezing, especially installations exposed to low temperatures. They can be installed inside the pipe or on its outer surface under thermal insulation.

Thanks to self-regulation, the cable adjusts the heating power to local temperature conditions and does not require an additional thermostat. It is suitable for water installations conducted outdoors, underground, and in unheated spaces.

Warranty terms

All Termofol products are covered by the manufacturer's warranty. The General Warranty Terms describe the scope of cover, the warranty period for individual product groups, installation requirements and how to file a claim. Keep your proof of purchase and the warranty card filled in by the installer — you'll need them when filing a claim.

Download warranty terms (PDF) PDF · 161 KB
Product manual Instructions for installation of heating cables TF-CW-SR Download PDF PDF · PL, EN
Product declaration of conformity Declaration of conformity for heating cable TF-CW-SR Download PDF PDF · PL
Product safety (GPSR) Safety warnings for the use of heating cables TF-CW-SR, TF-KZOP, TF-KGJZ, TF-KZT Download PDF PDF · PL

Reviews from our customers

Only customers who bought the product in our shop can post a review. We check this against an order placed from the customer account or with the same e-mail address and mark these reviews “Verified purchase”. We read every review before publishing it and publish both positive and negative ones. We only reject content that is unlawful, offensive, unrelated to the product or contains personal data. The product rating (stars) is the average of published reviews. We do not pay for reviews or offer discounts in return.

This product has no reviews yet. Be the first to rate it.

Related products

See all

Installing Termofol heating film is easy

Installation guide

Termofol heating films — see how quickly to go from purchase to installation

This short video walks you through the key installation stages, making it easier to understand how the system works and what you need to choose the right solution for your room.

Expert tips

See all
Types of Heating Mats. An Overview of TERMOFOL Systems for Indoor and Outdoor Applications General information

Types of Heating Mats. An Overview of TERMOFOL Systems for Indoor and Outdoor Applications

Heating mats today are much more than just underfloor heating for bathrooms. A few years ago, most investors associated heating mats solely with comfortable underfloor heating installed beneath ceramic tiles. Today, the market looks completely different. Modern heating systems include both mats designed for residential interiors and advanced outdoor solutions used to protect driveways, stairs, or […]

How to Choose a Heating Mat for a Room? A Practical Guide General information

How to Choose a Heating Mat for a Room? A Practical Guide

Choosing the right heating mat is more important than many investors realize. The selection of an appropriate heating mat should not be based solely on the area of the room. In practice, other factors also play a significant role: the heating function, type of flooring, insulation standard of the building, actual heating area, and the way the interior is used. That is why a well-chosen underfloor heating system operates comfortably, efficiently, and energy-saving for many years […]

Installation of Heating Mats Step by Step – Can You Do It Yourself? General information

Installation of Heating Mats Step by Step – Can You Do It Yourself?

Modern underfloor heating without complicated renovations. A few years ago, installing underfloor heating was mainly associated with major renovations, thick screeds, and complicated hydraulic installations. Today, modern heating mats allow for comfortable underfloor heating to be installed much faster and significantly less invasively. It is the simplicity of installation that has made electric heating mats very popular: during renovations […]

Heating Mats in Different Types of Properties – Where Do They Make the Most Sense? General information

Heating Mats in Different Types of Properties – Where Do They Make the Most Sense?

Termofol Expert: “Today, heating mats are chosen not only for comfort but primarily for the simplicity and flexibility of the entire system.” Just a few years ago, heating mats were mainly considered an additional solution — most often for bathrooms. Today, from the market perspective, it is clear that their role has significantly changed. Investors increasingly view electric underfloor heating as a conscious element of modern construction, rather than just a comfortable addition.

Termofol Newsletter

Subscribe to the newsletter and get a 5% discount

Consent is required.